6 x M10(3/8″) Studs

BB600-T6M10-C-BR 600A Covered Bus Bar

BB600-T6M10-C-BR provides 6 x M10(3/8″) stud connections with a 600 A current rating. The stud-only layout suits wiring assemblies built around cable lugs, without adding small screw terminals that are unnecessary for that connection format. Black and red versions share the same connection layout.

600 A

Current rating

6 x M10(3/8″)

Stud terminals

0

Screw terminals

Black/Red

Color versions

Product Details

BB600-T6M10-C-BR provides 6 x M10(3/8″) stud connections with a 600 A current rating. The stud-only layout suits wiring assemblies built around cable lugs, without adding small screw terminals that are unnecessary for that connection format. Black and red versions share the same connection layout.

BB600-T6M10-C-BR / mixed terminal configuration.

  • 01 Six M10(3/8″) lug positions
    Six M10(3/8″) studs provide a common connection layout for assemblies using larger lug-hole interfaces. There are no small screw terminals; all six positions use the same stud format.
  • 02 A covered terminal area
    The protective cover helps shield the connection area from incidental contact. Provide sufficient installation clearance for access to the terminals with the power isolated.
  • 03 A 600 A option in the range
    The 600 A current rating distinguishes this model from lower-current six-stud alternatives. Select it against the system load and installation conditions rather than the number of connected cables alone.

Specifications

Model BB600-T6M10-C-BR
Current rating 600 A
Maximum Voltage 48 V DC
Stud terminals 6 x M10(3/8″)
Bus Bar Material Nickel Plated Copper
Stud Material Stainless Steel
Base Material UL94-VO Rated, Glass Reinforced Thermoplastics
Cover Material Protective cover
Color Versions Black/Red
Overall Dimensions 178mm x 37.8mm x 56.2mm (L x W x H)

Terminal counts refer to one product assembly. Color versions are not added together. Mounting screws are not counted as electrical screw terminals.

Current rating applies to the product, not to each connection. Provide circuit protection separately. Inch sizes are approximate references, not interchangeable thread specifications.

Compare Connection Layouts and Ratings

Compare this model with other connection formats in the DAIERTEK range. Matching terminal counts do not establish mechanical interchangeability.

Model Current rating Stud terminals Screw terminals Layout reference
BB600-T6M10-C-BR
Current Product
600 A 6 x M10(3/8″) 0 This product
BB100-T4M8-C-BR 100 A 4 x M8(5/16″) 0 Stud-only layout
BB150-T6M6-C-BR 150 A 6 x M6(1/4″) 0 Stud-only layout
BB200-T6M6-B 200 A 6 x M6(1/4″) 0 Stud-only layout
BB300-T6M10-C-BR 300 A 6 x M10(3/8″) 0 Stud-only layout
BB400-T6M8-C-BR 400 A 6 x M8(5/16″) 0 Stud-only layout

Counts are totals for each listed assembly. Dual assemblies are not rated by adding two current values. Black/red options do not mean that a pair is supplied.

Common DC Connections in Practice

Typical uses for protected vehicle and onboard electrical installations.

Auxiliary power compartments

The 6 x M10(3/8″) stud layout provides a connection format for a vehicle auxiliary-power assembly. Assess the cable, overcurrent protection and installation conditions independently of the 600 A product rating.

RV and commercial vehicle electrical builds

Use within a protected electrical compartment where cable lugs need defined connection positions. Leave clearance for cable bends and access to the terminals during maintenance.

Application examples describe potential installation contexts, not verified fitment to a particular vehicle. Keep live connections protected from water, conductive debris and accidental contact.

Reference Drawing

Request Technical Documents

Interested in this product?

Contact us for samples, product documentation and supply enquiries for aftermarket distribution or OEM projects.